Skip to content

Version info

Version: v1.0.1

Date: 21.08.2025

  • Specified the description of how to measure the distance from the acromion lateral border to the outer belt edge in the documentation (closes #46)
  • Updated values z_DR and y_DR in the master file to fulfil target distance from the acromion lateral border to the outer belt edge

Version: v1.0.0

Date: 30.07.2025

  • Fixed added mass calculation (closes #37)
  • Implemented a parameter for contact flag DEPTH (closes #38)
  • Implemented a parameter to increase positioning beam force (closes #39)
  • Added version number to assessment notebook (closes #40)
  • Introduced node set for all HBM nodes for initial velocity generation keyword (closes #43)
  • Updated distance measurement to determine correct belt path from distance "B" to distance "A". (closes #42)
  • Deleted Acromion nodout definition from instrumentation requirements in documentation, as nodout is not used in the assessment notebook

Version: v0.9.1

Date: 09.07.2025

  • Added assessment notebooks which process csv input

Version: v0.9.0

Date: 21.03.2025

  • Increased element size of load cells to avoid added mass if non default time step is used
  • Changed parameter definition to avoid referencing parameter with "-" before parameter name (movSEz, movFRz, movKSx)
  • Updated target positioning angles, as 3 test data sets were added to GS2
  • Changed node name "seat" to "testbed" in 02_quality_criteria.def. No influence as channel is not needed
  • Cosmetics to shoulder belt angle checker (text was not load case sensitive)
  • Added remark on shell/solid set definition from documentation also to master file

Version: v0.8.7

Date: 11.03.2025

Renamed test data files (closes #36)

Version: v0.8.6

Date: 07.03.2025

  • Deleted termination switch. Simulation needs to be run as long as test data
  • Changed tload to 250ms
  • Changed in-crash time for simulation time checker to 240ms
  • Modified contact settings. Set BSORT and SFS and SFM to default
  • Implemented score calculation to assessment notebook
  • Implemented added mass calculation to assessment notebook
  • Cosmetic adaptations

Version: v0.8.5

Date: 22.01.2025

  • Updated test data *csv files for the GS1 and GS2.1 load case. (closes #35)
  • Added rib fracture risk plot with NRF=0, NFR=1+, NRF=2+ NRF=3+

Version: v0.8.4

Date: 17.01.2025

  • Added PMHS data to notebook from test S00302, S00303 and S00304 (GS2 configuration)

Version: v0.8.3

Date: 13.01.2025

  • Fixed simulation time check in assessment notebook (closes #34)

Version: v0.8.2

Date: 19.12.2024

  • Added information on the procedure to determine the shoulder belt angle in more detail to the documentation. (closes #33)
  • Added error termination guide to the documentation

Version: v0.8.1

Date: 17.12.2024

  • Added PMHS data to assessment notebook

Version: v0.8.0

Date: 11.12.2024

  • Added belt include with extended shoulder belt (closes #31)
  • Updated the coordinates of slip-ring (closes #32)

Version: v0.7.1

Date: 09.12.2024

  • Added simulation duration check
  • Cosmetic changes

Version: v0.7.0

Date: 06.12.2024

  • Updated referenced test data in notebeook (closes #27)
  • Updated buckle slip ring position (closes #28)
  • Added parameter to rotate lap belt segment (closes #29)
  • Added chest deflection data to assessment notebook (closes #30)
  • Cosmetics in assessment notebook

Version: v0.6.1

Date: 22.11.2024

  • Update to the assessment notebook
  • Changes to the chest deflection calculation
  • Experimental chest deflection curves added for GS1

Re-run of the notebook required.

Version: v0.6.0

Date: 04.11.2024

  • Update position of buckle slip ring and add a buckle (closes #28).
  • Add referenced literature for coordinate system definition in T8 vertebrae.
  • Update notebook to compare shoulder belt angle to the range observed in the specific load case (GS1, GS2, GS2.1).

Version: v0.5.1

Date: 17.10.2024

  • Update on documentation (typos and description of instrumentation requirements)

Version: v0.5.0

Date: 09.10.2024

  • Added nodout for chest deflection assessment.
  • Updated notebook (seat belt force component and plot renamed to avoid overwriting).
  • Update belt force component (resultant instead of x) in definition file (already pushed in previous version).

Re-run required to assess chest deflection.

Version: v0.4.0

Date: 01.10.2024

  • Deleted the respective database element beams to prevent notebook error.
  • Corrected typos in "final checks" slide in the documentation.
  • Add option to choose if both or one of the *CONSTRAINT_IN_ options (SOLID/SHELL) are used.
  • Updated GS2.1 acc curve again to ensure sled does not move before settling is finished.

Re-run only necessary for GS2.1.

Version: v0.3.1

Date: 02.09.2024

  • Removed values before t0 from GS2.1 acc curve.

Re-run only necessary for GS2.1.

Version: v0.3.0

Date: 27.08.2024

  • D-Ring (position updated and made movable)
  • Slipring (lockup time added)
  • Position of footrest
  • Contact to footrest in settling Phase
  • GS2.1 acc curve offset
  • Spikes in acceleration curve deleted
  • Load case dependent HBM posture implemented
  • Update of seat mass in calculations.k

Version: v0.2.0

Date: 13.08.2024

  • Update to offer users a selection of Gold Standard setups:
  • Gold Standard 1 (Shaw et al. 2009): 40 km/h, no load limit, mid-sized male PMHS
  • Gold Standard 2: 30 km/h, 3 kN load limit, mid-sized male PMHS
  • Gold Standard 2.1: 30 km/h, 2 kN load limit, small female PMHS
  • Reduced belt damping in settling phase to improve belt shape/fit.
  • Changed load cell modelling (seat, knee, foot rest) from beam elements to cross sections (enabling 10 kHz output frequency without creating huge elout files, as they include all rib elements).
  • Changed method of restraining feet to foot support during loading phase (*CONSTRAINED_SOLID_IN_SOLID_PENALTY and *CONSTRAINED_SHELL_IN_SOLID_PENALTY instead of rigid beams).

Version: v0.1.1

Date: 22.07.2024

Update to enable HBM rotation to achieve the desired shoulder belt angle (range) observed in the PMHS tests.

Version: v0.1.0

Date: 18.07.2024

Initial beta version release for testing within the QualiPro HBM4VT group.