Version info¶
Version: v1.0.1¶
Date: 21.08.2025
- Specified the description of how to measure the distance from the acromion lateral border to the outer belt edge in the documentation (closes #46)
- Updated values z_DR and y_DR in the master file to fulfil target distance from the acromion lateral border to the outer belt edge
Version: v1.0.0¶
Date: 30.07.2025
- Fixed added mass calculation (closes #37)
- Implemented a parameter for contact flag DEPTH (closes #38)
- Implemented a parameter to increase positioning beam force (closes #39)
- Added version number to assessment notebook (closes #40)
- Introduced node set for all HBM nodes for initial velocity generation keyword (closes #43)
- Updated distance measurement to determine correct belt path from distance "B" to distance "A". (closes #42)
- Deleted Acromion nodout definition from instrumentation requirements in documentation, as nodout is not used in the assessment notebook
Version: v0.9.1¶
Date: 09.07.2025
- Added assessment notebooks which process csv input
Version: v0.9.0¶
Date: 21.03.2025
- Increased element size of load cells to avoid added mass if non default time step is used
- Changed parameter definition to avoid referencing parameter with "-" before parameter name (movSEz, movFRz, movKSx)
- Updated target positioning angles, as 3 test data sets were added to GS2
- Changed node name "seat" to "testbed" in 02_quality_criteria.def. No influence as channel is not needed
- Cosmetics to shoulder belt angle checker (text was not load case sensitive)
- Added remark on shell/solid set definition from documentation also to master file
Version: v0.8.7¶
Date: 11.03.2025
Renamed test data files (closes #36)
Version: v0.8.6¶
Date: 07.03.2025
- Deleted termination switch. Simulation needs to be run as long as test data
- Changed tload to 250ms
- Changed in-crash time for simulation time checker to 240ms
- Modified contact settings. Set BSORT and SFS and SFM to default
- Implemented score calculation to assessment notebook
- Implemented added mass calculation to assessment notebook
- Cosmetic adaptations
Version: v0.8.5¶
Date: 22.01.2025
- Updated test data *csv files for the GS1 and GS2.1 load case. (closes #35)
- Added rib fracture risk plot with NRF=0, NFR=1+, NRF=2+ NRF=3+
Version: v0.8.4¶
Date: 17.01.2025
- Added PMHS data to notebook from test S00302, S00303 and S00304 (GS2 configuration)
Version: v0.8.3¶
Date: 13.01.2025
- Fixed simulation time check in assessment notebook (closes #34)
Version: v0.8.2¶
Date: 19.12.2024
- Added information on the procedure to determine the shoulder belt angle in more detail to the documentation. (closes #33)
- Added error termination guide to the documentation
Version: v0.8.1¶
Date: 17.12.2024
- Added PMHS data to assessment notebook
Version: v0.8.0¶
Date: 11.12.2024
- Added belt include with extended shoulder belt (closes #31)
- Updated the coordinates of slip-ring (closes #32)
Version: v0.7.1¶
Date: 09.12.2024
- Added simulation duration check
- Cosmetic changes
Version: v0.7.0¶
Date: 06.12.2024
- Updated referenced test data in notebeook (closes #27)
- Updated buckle slip ring position (closes #28)
- Added parameter to rotate lap belt segment (closes #29)
- Added chest deflection data to assessment notebook (closes #30)
- Cosmetics in assessment notebook
Version: v0.6.1¶
Date: 22.11.2024
- Update to the assessment notebook
- Changes to the chest deflection calculation
- Experimental chest deflection curves added for GS1
Re-run of the notebook required.
Version: v0.6.0¶
Date: 04.11.2024
- Update position of buckle slip ring and add a buckle (closes #28).
- Add referenced literature for coordinate system definition in T8 vertebrae.
- Update notebook to compare shoulder belt angle to the range observed in the specific load case (GS1, GS2, GS2.1).
Version: v0.5.1¶
Date: 17.10.2024
- Update on documentation (typos and description of instrumentation requirements)
Version: v0.5.0¶
Date: 09.10.2024
- Added nodout for chest deflection assessment.
- Updated notebook (seat belt force component and plot renamed to avoid overwriting).
- Update belt force component (resultant instead of x) in definition file (already pushed in previous version).
Re-run required to assess chest deflection.
Version: v0.4.0¶
Date: 01.10.2024
- Deleted the respective database element beams to prevent notebook error.
- Corrected typos in "final checks" slide in the documentation.
- Add option to choose if both or one of the
*CONSTRAINT_IN_options (SOLID/SHELL) are used. - Updated GS2.1 acc curve again to ensure sled does not move before settling is finished.
Re-run only necessary for GS2.1.
Version: v0.3.1¶
Date: 02.09.2024
- Removed values before t0 from GS2.1 acc curve.
Re-run only necessary for GS2.1.
Version: v0.3.0¶
Date: 27.08.2024
- D-Ring (position updated and made movable)
- Slipring (lockup time added)
- Position of footrest
- Contact to footrest in settling Phase
- GS2.1 acc curve offset
- Spikes in acceleration curve deleted
- Load case dependent HBM posture implemented
- Update of seat mass in calculations.k
Version: v0.2.0¶
Date: 13.08.2024
- Update to offer users a selection of Gold Standard setups:
- Gold Standard 1 (Shaw et al. 2009): 40 km/h, no load limit, mid-sized male PMHS
- Gold Standard 2: 30 km/h, 3 kN load limit, mid-sized male PMHS
- Gold Standard 2.1: 30 km/h, 2 kN load limit, small female PMHS
- Reduced belt damping in settling phase to improve belt shape/fit.
- Changed load cell modelling (seat, knee, foot rest) from beam elements to cross sections (enabling 10 kHz output frequency without creating huge elout files, as they include all rib elements).
- Changed method of restraining feet to foot support during loading phase (
*CONSTRAINED_SOLID_IN_SOLID_PENALTYand*CONSTRAINED_SHELL_IN_SOLID_PENALTYinstead of rigid beams).
Version: v0.1.1¶
Date: 22.07.2024
Update to enable HBM rotation to achieve the desired shoulder belt angle (range) observed in the PMHS tests.
Version: v0.1.0¶
Date: 18.07.2024
Initial beta version release for testing within the QualiPro HBM4VT group.