Version info¶
Version: v1.0.0¶
Date: 29.07.2025
- Fixed added mass calculation (closes # 8)
- Implemented a parameter for contact flag DEPTH (closes # 9)
- Added version number to assessment notebook (closes # 10)
- Modified positioning beams release method. Beams are deactivate at contact between hub and knee instead of deactivation at the end of the settling phase (closes #11)
- Renamed parameter Fpos to Fbeam to be consistent with other setups
Version: v0.1.14¶
Date: 10.04.2025
- Cosmetics: Added a remark to keep a defined clearance between hub and HBM to facilitate filtering in the assessment notebook.
Version: v0.1.13¶
Date: 28.03.2025
- Corrected calculation of HBM y rotation. Rerun only required if z_rt is set to "-1"
- Cosmetics
Version: v0.1.12¶
Date: 25.03.2025
- Corrected calculation of HBM y rotation. Rerun only required if z_rt is set to "-1". (closes #7)
Version: v0.1.11¶
Date: 20.03.2025
- Reduced TRamp to 10ms to fasten up settling time
- Introduced a parameter to control tension force in positioning beams
- Increased default tload to 200ms to cover necessary simulation duration for the low speed loadcase
- Changed parameter definition to avoid referencing parameter with "-" before parameter name (movSz, movFRz)
- Cosmetics: changed node name "table" to "Hub_left" in 02_quality_criteria.def. No influence as channel is not needed
- Updated assessment notebook to evaluate all three loadcases in one notebook
- Added force tolerance value to settings file
- Cosmetics: deleted double defined paths in notebook
Version: v0.1.10¶
Date: 12.03.2025
- Updated setup names in simulation time check in assessment notebook (closes #6)
- Cosmetic updates to notebook
- Introduced separate parameter with changed sign to avoid referencing parameter with "-" before parameter name (y_rot)
- Changed parameter definition to avoid referencing parameter with "-" before parameter name (movSz, movFRz)
- Inserted "Save and reopen master file" at step 5 to assure the correct sternum angle measurement
Version: v0.1.9¶
Date: 07.03.2025
- Simulation time checker adapted to consider different in-crash times in different load cases
- Implemented score calculation to assessment notebook
- Implemented added mass calculation to assessment notebook
- Cosmetic adaptations
Version: v0.1.8¶
Date: 04.02.2025
- Cosmetic updates
Version: v0.1.7¶
Date: 24.01.2025
- Added Information on the chosen position strategy (closes #2)
- Cosmetic changes to assessment notebook
Version: v0.1.6¶
Date: 13.01.2025
- Delayed the start of the impactor by 5ms to provide time for the pelvic movement to complete. (closes # 5)
Version: v0.1.5¶
Date: 13.01.2025
- Fixed simulation time check in assessment notebook (closes #4)
Version: v0.1.4¶
Date: 17.12.2024
- Added simulation duration check to assessment notebook
- Cosmetic changes (rename parameter to be consistent)
Version: v0.1.3¶
Date: 06.12.2024
- Update to README
Version: v0.1.2¶
Date: 29.11.2024
- Update to impactor foam material (closes issue #3)
- Update to the documentation
Version: v0.1.1¶
Date: 01.10.2024
- Added a beam visualising the impactor axis
- Added the assessment notebook
Version: v0.1.0¶
Date: 02.09.2024
Initial beta version release.